Filter Results By:

Products

Applications

Manufacturers

Protection Relay

acts as a circuit breaker in the event of a fault.


Showing results: 646 - 660 of 665 items found.

  • FTL Test Block

    SecuControl inc.

    FTL testblock with dust cover and current disconnect pinThe FTL is a test block for interfacing substation devices (protection relays, fault recorders, revenue meters, ... ) to the voltage and current transformers and to other equipment on the system side of a power grid. The FTL test block uses disconnect pins to isolate the substation devices from the system side equipment. Once isolated, secondary injection can be performed using banana jacks on the front side of the test block.

  • 32-CH Isolated DIO PCI Cards

    PCI-7230/33/34 - ADLINK Technology Inc.

    ADLINK"s PCI-723X series are 32-CH isolated input and/or output cards which provide a 2,500 V optical isolation protection. The wide input range of the PCI-7230 and PCI-7233 makes it easy to sense the status of external devices. The non-polarity characteristic is suitable for a wide variety of industry applications. The PCI-7230 and PCI-7234 devices also feature a wide output range from 5 to 35 V, which is suitable for relay driving and industrial automation applications. The PCI-7234P provides current-source output capability. The PCI-7230 and PCI-7233 also provide two interrupt sources on digital input channels. The PCI-7233 also features a change-of-state (COS) function that generates an interrupt when any digital input changes its state.

  • Enlarge Environmental Chamber

    REXMED REC-450 - REXMED Industries Co., Ltd.

    MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-250 - REXMED Industries Co., Ltd.

    MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-400 - REXMED Industries Co., Ltd.

    MOD. REC-400, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,506 Watts, 11,962 BTU/hr, 3,020 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-280 - REXMED Industries Co., Ltd.

    MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-480 - REXMED Industries Co., Ltd.

    MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-200 - REXMED Industries Co., Ltd.

    MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • UNI-T Series

    Weshine Electric Manufacturing Co., Ltd

    mainly used to measure the wire resistance of cables, the contact resistance ofswitches, connectors, relays, the resistance of coils, motors, transformer windings, and equipment enclosures, lightning protection belts, ground beams, structures, cabinets, steel bars, Test the connection resistance between metal components of water pipes, windows, guardrails, radiators, assembly lines, etc. It is widely used in telecommunications, electric power, meteorology, computer rooms, oil fields, power distribution lines, tower transmission lines, gas stations, factory grounding grids, lightning rods, etc.

  • Instrumentation/Electronics

    Thames Side Sensors Limited

    Junction Boxes for 4 or 8 load cells in ABS, Aluminium or Stainless Steel (optionally with ATEX approval)Intelligent Junction Box for individual monitoring of load cell performance and error checking of up to 4 load cellsSimple weighing transmitters (with analogue output for connection to a PLC) or high speed transmitters with built-in weight indication, external communications, set points and dedicated check weigher functionsPurpose designed weight indicators with external communications, ATEX approval for use in hazardous areas and IP69K protection for use in harsh, wash-down environmentsDedicated weighing controllers for batching, filling, check weighing, truck weighing and axle weighing, with communications and relay outputsInstrumentation/electronics with Weights and Measures approvals (legal-for-trade), i.e. OIML R76 and EN45501:2015 (NAWI)Remote displays for secondary weight indication at a different locationLoad cell tester with intelligent diagnosticsLoad cell simulator

  • Single-Phase Relays

    Series S - Teledyne Defense Electronics Relays & Coax Switch

    The Series S single-phase relays are designed for all types of loads. The design incorporates an SCR or triac output. The relays utilize optical isolation to protect the control from load transients. All contain an internal snubber for output protection. High-current models are excellent for motor and UPS control. Zero-Cross or Random switching options available.Available options include:​S24D25 25A, 12-280Vrms, 600Vpeak Load; 4-30Vdc Control; Zero-CrossS24R40 40A, 12-280Vrms, 600Vpeak Load; 3-30Vdc Control; RandomS24D40 40A, 12-280Vrms, 600Vpeak Load; 4-30Vdc Control; Zero-CrossS24D40 40A, 12-280Vrms, 600Vpeak Load; 90-240Vac/Vdc Control; Zero-CrossS48R25 25A, 24-520Vrms, 1200Vpeak Load; 4-30​Vdc Control; Random​​S48D25 25A, 24-520Vrms, 1200Vpeak Load; 5-30​Vdc Control; Zero-CrossS48D50 50A, 24-520Vrms, 1200Vpeak Load; 5-30​Vdc Control; Zero-Cross​​S48R75 75A, 24-520Vrms, 1200Vpeak Load; 90-24​​​​0Vac/Vdc Control; Zero-CrossS48A50 50A, 24-520Vrms, 1200Vpeak Load; 90-240Vac/​Vdc Control; Zero-CrossS48A50-22/R 50A, 24-520Vrms, 1200Vpeak Load; 17-80Vac/Vdc Control; Zero-CrossS48R125 125A, 24-520Vrms, 1200Vpeak Load; 4-30Vdc Control; RandomS60D50 50A, 24-690Vrms, 1600Vpeak Load; 7-30​Vdc Control; Zero-Cross​​S60D125 125A, 24-660Vrms, 1600Vpeak Load; 7-30​Vdc Control; Zero-Cross

  • Industrial UPS (Wide-temperature)

    SSG Series - Falcon Electric, Inc

    • -20°C to 55°C temperature range. The SSG UPS is agency-certified (UL, cUL, CE) to operate reliably in demanding environments.• Long-life UPS: true on-line, industrial Tested and designed with robust components and materials, the SSGassures reliable operation and a long service life in stressful environments. It is a true on-line industrial UPS.• 12-year rated batteries cut service costs The long-life batteries cut frequent battery replacements and maintenance costs. They have a 12-year life at 25°C and 4 years at 50°C.• Extended battery banks The battery banks are easily expandable to provide minutes to hours of extra battery runtime. • Available options / Advanced communications NEMA 3R-rated enclosures, environmental protection, remote UPS management, environment sensors, relay cards – and much more.• Falcon – recognized for quality and reliability Falcon Electric is a recognized authority in industrial UPS solutions. Our technical expertise assures you find the right solution – the first time

  • Industrial UPS (Ultra-wide temperature) – 1kVA to 3kVA

    SSG-RP Series - Falcon Electric, Inc

    *-30°C to 65°C temperature range The SSG-RP UPS is agency-certified (UL, cUL, CE) to operate reliably in ultra-wide temperature environments. All 120V models are also UL 508 listed.*Long-life UPS: true on-line, industrial Tested and designed with robust components and materials, the SSG-RP assures reliable operation and a long service life in very demanding temperature environments. It is a true on-line industrial UPS.*Extreme temperature batteries. The batteries used inside the UPS were specifically selected due to their wide operational range of -40°C to 80°C. They have a 10-year life at 25°C.*Extended battery banks The battery banks are easily expandable to provide minutes to hours of extra battery runtime.*Available options / Advanced communications. NEMA 3R-rated enclosures, environmental protection, remote UPS management, environment sensors, relay cards – and much more.*Falcon – recognized for quality and reliability Falcon Electric is a recognized authority in industrial UPS solutions. Our technical expertise assures you find the right solution – the first time.

  • 6TL-3X INLINE Header Conveyor 765 mm Length

    AQ580 - 6TL Engineering

    - PCB up to 600mm length 400 mm width- Programmable transfer speed up to 1 m/s- Automatic Previous/Next speed adjustment- 2D Code reader w/automatic positioning- Pre-wired for second 2D Code reader- Automatic width setting- PC for line management w/UPS with 20” monitor and keypad in adjustable position arm- 24 Ports PoE Switch- Power inlet rack with current protections and line safety relay- Top cover and door w/safety contacts inhibiting line modules while active- Mechanisms self-test- Width auto-adjustment and cyclic width- Non-contact electronic stop of the PCB- 4U Free on the 19” Rack- Interfaces SMEMA 9851 y IPC-HERMES 9852- CE certified

  • High voltage Flexible range Regulated DC Power Supplies

    PSF-H Series - Texio Technology Corp.

    * Main Applications: High-voltage capacitors or relays used for hybrid cars, electric cars, solar power system and high-voltage LED lighting equipment.* 6 times of flexible output range: PSF-800H covers output for several units of conventional type regulated power supplies within 800W ( max voltage 800V, max current 6A. ).* Constant Power Control: CP mode is available in addition to CV and CC modes.* Changeable setting style: Vertical or horizontal setting by 90rotating panel.* Sequence Operation: Stand-alone sequence is available with the insidememory programmed by PC, through the optional control board (IF-60GP, IF-60RU).* Master-slave parallel operation: Possible to increase the output current by master-slave parallel connection of the same model (up to 2 units).* Various functions are available: Output OFF timer, 3-point preset memory, Remote sensing, External analog control, OVP/OCP/OHP protections

Get Help